SEVENBOND® FR Aluminium Composite Panel is a lightweight aluminium panel comprising of two aluminium sheets and a core made of mineral-filled thermoplastic. It is highly recommended when resistant to flame spread in the event of fire is desired. For any external façade of 18m or higher, SEVENBOND® FR should be used as the external wall cladding. It is tested and has passed all the major fire tests under the British, European and American standards.
Product certified to MS 2571 and issued with CIDB PPS certificate for Exterior & Interior Wall Cladding
Fire resistant
Ultra-modern look and excellent flatness
Light weight and rigid
Great formability and stability
Excellent weather resistance
Various uniform colour options
Low maintenance
Full manufacturer’s warranty
Eco-friendly materials
The consideration for fire and safety in the construction of any buildings is a key design factor. In the event of a fire, the risk of human lives is greater in high rise building such as hotels, service apartments and offices, purely due to the heavy concentration of people in these buildings. However, these risks can be drastically reduced by taking appropriate fire protection measures such as having sprinkler system, fire doors and firewall grade party walls.
In the case of external wall cladding, the use of SEVENBOND® FR panel will have reduced the spread of flame thus minimising the chance of loss of lives due to fire.
The SEVENBOND® FR series with its fire-resistant core materials fully complies with the most demanding fire safety standards worldwide and is clearly illustrated in the table below:
Testing Standard | Flame Spread | Smoke Emission | Burning Droplets | Temperature | Self Extinguishing | With System | Result |
---|---|---|---|---|---|---|---|
BS 8414-1 | Passed | ||||||
BS 476 : Part 6 & 7 | Class O | ||||||
EN 13501-1 | B, s1, d0 | ||||||
ASTM E-84 (NFPA 255) | Class A | ||||||
NFPA 285 | Passed |
The SEVENBOND®-FR series are supreme fire-resistant materials and fully comply with the most demanding fire safety standards worldwide as shown in the fire classifications table below:
TEST | RESULT | TEST LAB | COUNTRY |
---|---|---|---|
BS 8414-1 | Passed | SIRIM | Malaysia |
BS 476 : Part 6 & 7 | Class O | SIRIM TUV-SUD-PSB | Malaysia Singapore (1) |
EN 13501-1 | B, s1, d0 | Intertek | Europe |
ASTM E-84 (NFPA 255) | Class A | Intertek | USA |
NFPA 285 | Passed | Intertek | USA (2) |
Notes:
1) BS 476 : Part 6 and 7 tests were conducted in SIRIM Malaysia and TUV-SUD-PSB, Singapore. The tests conducted in Singapore were on the surface where the aluminium skin was removed. This is to ensure even the FR core material meets the Class O classification.
2) EN 13501-1 is the European fire testing standard. In Europe, a B S1 d0 rating is required for ACP panels used as external cladding for high rise buildings.
3) NFPA E84 and NFPA 285 are the fire testing standard of the National Fire Protection Association of USA. The NFPA 285 is a multi-story fire propagation test and is one of the most stringent test. The passing of these two tests are a prerequisite for ACP panels to be used for high rise projects.
With a variety of finishes and excellent properties, SEVENBOND® FR panel allows the designer to exercise his full spectrum of his imagination and creativity but without compromising on safety against fire. SEVENBOND FR® is suitable for the various applications listed below:
External and interior wall cladding
Modern building facelift and refurbishment
Fins and copings
Tunnel linings and ceilings
Back pan for curtain wall system